Reverse Less Invasive Stabilization System of Distal Femur Plating for Nonunion of Proximal Femoral Fractures

盛加根,张长青,苏琰,程相国
DOI: https://doi.org/10.3760/cma.j.issn.1671-7600.2008.11.004
2008-01-01
Abstract:Objective To report the results of reverse less invasive stabilization system of distal femur (LISS-DF) plating for nonunion of proximal femoral fractures. Methods Seventeen cases of postoperative nonunion of proximal femoral fractures were treated with contralateral reverse LISS-DF plating, including 8 eases of hypertrophy type, 6 cases of atrophy type, and 3 cases of bone defect type. Bone grafting was performed for all cases, including 6 cases of local sliding plus bony callus grafting, 9 cases of autolngous iliac bone grafting, and 2 cases of free vascularized fibular grafting. Results All cases were followed up from 5 months to 32 months, with a mean period of 13.8 months. The results showed all cases healed smoothly without wound infection or fixator failure. The mean time for full weight bearing was 16.5 (11 to 28) weeks. The hip joint function was evaluated by Sanders Traumatic Hip Rating Scale only to find 10 excellent, 5 good and 2 fair cases, with the excellent and good rate being 88.2%. Conclusion AS reverse LISS-DF plating plus autologous bone grafting can significantly promote fracture union, it is an effective treatment of nonunion of proximal femoral fractures.
What problem does this paper attempt to address?