A Report on an Improved NUSS Procedure and Its Clinical Application

李国庆,梅举,丁芳宝,肖海波,胡丰庆,王明松,谢晓,陈寅,王磊
DOI: https://doi.org/10.3760/cma.j.issn.0253-3006.2013.07.004
2013-01-01
Abstract:Objective To present the improved NUSS procedure for children with funnel chest.Methods From February 2010 to January 2011,103 patients (93 males and 10 females)with funnel chest (Pectus Excavatum) underwent surgery in this institution.They aged from 3 to 14 years.There were 10 cases with large area of flat chest plus funnel chest,11 cases with asymmetrical funnel chest which including 3 cases with partial pectus carinatum like asymmetrical uplift,and 5 cases with recurrent funnel chest.With the help of computer-aided design,we invented the steel bars that had independent intellectual property rights.The steel bars were divided into two types according to their thickness and width.One end of the bar was fused with a stabilizer and the other end connected to an introducer or a stabilizer.There were many different pads choices to match the different types of funnel chest.Patients were placed supine position.Two incisions,with length about 1.5-2.5 cm and deep to the rib periosteum were made along anterior axillary lines on the both sides.Along the outer space of the periosteum,the separation toward the highest point of thoracic chest was made,the highest point and the lowest point of sternum were on the same line.A thoracoscope to guide the bar was inserted through a small incision at the middle axillary line and the 8th intercostal space.The steel bar with an introducer on the head was pushed from the right incision along posterior to the sternum and ribs,anterior to the heart and lungs,and through the highest point of left thoracic chest,ending at the left incision.Then the introducer was removed,and the bar was flipped.The metal plates (stabilizers) were connected on the left end of the bar to support the bar and kept it in place.The stabilizer on either side was secured with sutures.Results Good orthopedic effect was achieved in all patients.One steel bar per patient was used for 8 cases with large area flat chest plus funnel chest,while the NUSS procedure required two steel bars.All patients after surgery could stay lateral positions.Conclusions In this improved NUSS procedure,the steel bars do not need to be processed during surgery,the installation and removal of steel bars are safer,more convenient,and no restrictive to the growth and development of children's chest wall.This procedure has less injury,fewer complications,lighter and shorter postoperative pain.
What problem does this paper attempt to address?