18F-Alfatide II Automated Preparation Based on 18F-Minireactor and Micropet/ct Imaging in Tumor

Zhang Jian,Zhou Xiaobao,Shi Qin,Sun Yuyun,Zhang Yingjian,Zhang Yongping,Wang Mingwei
DOI: https://doi.org/10.3760/cma.j.issn.2095-2848.2019.04.002
2019-01-01
Abstract:Objective To develop the automated preparation of 18F-Alfatide II using newly-designed 18F-minireactor and perform 18F-Alfatide D microPET/CT imaging in tumor.Methods The automated preparation of 18F-Alfatide H was developed by using 18F-microreactor and water phase Al18F-chelating method,and the radiochemical yield and quality analysis were measured.The nude mice bearing breast tumor ZR-75-1 and nasopharyngeal tumor CNE1 were established(n = 3 respectively).MicroPET/CT imaging was performed at 0.5,1.0 and 2.0 h after the injection of 18F-Alfatide II.The region of interest(ROI)was depicted and the tumor/muscle(T/M)ratio was calculated.Results 18F-Alfatide II was automatically prepared with the total synthesis time of 40 min,the radiochemical yield of(28±6)%(no decay corrected,n=11),and the radiochemical purity >97%.All quality analysis indexes accorded with the radiopharmaceutical requirements.18F-Alfatide II microPET/CT images of ZR-75-1 and CNE1 tumors were clear due to the high radioactivity uptake of tumor lesions(T/M ratio was greater than 4.0 at 1.0 h after injection).Conclusion Based on the 18F-minireactor,the,8F-Alfatide II can be prepared successfully with short synthesis time and high radiochemical yield,which can help the application studies in 18F-Alfatide II microPET/CT imaging.