Application of Metagenomics Next-Generation Sequencing in Monitoring Legionella Pneumophila Infection after Allogeneic Hematopoietic Stem Cell Transplantation

Yuan Lili,Zhao Huizheng,Zhang Jianping,Wang Fang,Li Nannan,Zhao Xingzhen,Chen Xue,Zhang Yang,Nie Daijing,Cao Panxiang,Wang Mangju,Liu Ming,Liu Mingyue,Liu Hongxing
DOI: https://doi.org/10.3760/cma.j.issn.1009-9921.2019.12.008
2019-01-01
Abstract:Objective To investigate the application of metagenomic next-generation sequencing (mNGS) in detection of the rare or difficult-to-cultivate pathogens. Methods One patient with acute lymphoblastic leukemia who went through allogeneic hematopoietic stem cell transplantation (allo-HSCT) developed symptoms of infection after transplantation. Conventional microbial culture, polymerase chain reaction (PCR), and mNGS combined with biological information analysis were performed with plasma and cerebrospinal fluid samples, the anti-infective treatment was adjusted according to the test results, and the efficacy was assessed. Results No suspected pathogens were detected by microbial culture and PCR in the cerebrospinal fluid and plasma samples since the patient developed infection symptoms. However, Legionella pneumophila was analyzed by mNGS in the cerebrospinal fluid specimen on day 23 after allo-HSCT (reads count: 19 655), and it was considered as the principal pathogen after comprehensively evaluating the patient's clinical manifestations and the test results. Then the antimicrobial treatments were adjusted according to the patient's clinical manifestations and laboratory test results, and the number of gene sequences of Legionella pneumophila was monitored by mNGS method. Azithromycin, tigecycline, and other antibiotics effective for Legionella pneumophila were used after detecting this pathogen. A total of 15 mNGS analysis were performed during the 5-month period, and the highest number of Legionella pneumophila sequences monitored in the cerebrospinal fluid was 2 226, the lowest was 253 and eventually turned negative. The clinical symptoms and treatment outcomes were consistent with the mNGS monitoring results. Conclusions The mNGS technology has significant value in detection of the rare and difficult-to-cultivate pathogens. The mNGS technology provides a valuable supplement to microbial culture and PCR methods. Key words: High-throughput nucleotide sequencing; Metagenome; Hematopoietic stem cell transplantation; Legionella pneumophila
What problem does this paper attempt to address?