Multi-modality Imaging in the Patients with Myocardial Infarction after Coronary Artery Bypass Graft and Autologous Bone Marrow Stem Cell Transplantation
Lu Guoxiu,Hao Shanhu,Wang Zhiguo,Zhang Tong,Wang Huishan,Zhang Guoxu
DOI: https://doi.org/10.3760/cma.j.issn.2095-2848.2017.06.001
2017-01-01
Abstract:Objective To evaluate the value of multi-modality imaging (PET/CT+CAG+CMRI) in post myocardial infract (MI) patients followed coronary artery bypass graft (CABG) and autologous bone marrow stem cell (BMSC) therapy.Methods A total of 43 patients with MI (27 males, 16 females, age range: 47-72 years) were prospectively enrolled in the year 2012 between January and December.All patients underwent CABG+BMSC transplantation and were divided into 3 groups according to the time interval between two treatments (group 1: 0-3 d;group 2: 4-14 d;group 3: 15-30 d).All patients were orderly scanned with CMRI, PET/CT (13N-NH3·H2O/18F-FDG) and CAG at different time-points pre-/post-treatment.The quantitative parameters included vascular stenosis degree(VSD), LVEF, percentage size of infarction (PSI), the number of segments in mismatched myocardial perfusion/metabolic and the K value for radioactive distribution grading.One-way analysis of variance and the least significant difference t test were used to compare parameters before and after treatment in the same group and among three different groups.Results Regarding PET/CT diagnostic efficacy of abnormal myocardial segments, the sensitivity, specificity, positive predictive value and negative predictive value were 95.4%(540/566), 87.3%(144/165), 96.3%(540/561) and 84.7%(144/170), respectively.After CABG and BMSC transplantation treatments for 12 months, VSD decreased significantly((69.1±9.5)%;F=12.854, P<0.05), comparing with the baseline ((74.8±7.9)%;t=3.074, P<0.05).Comparing to the baseline, LVEF in 3 groups increased slightly(F values: 0.906,0.298,0.059, all P>0.05).PSI of patients in group 2 decreased greatly after 12 months treatment ((35.70±12.59)%;F=3.792, t values:-2.916-4.059, all P<0.05).K values for radioactive distribution grade decreased obviously after 1 month and 12 months treatment comparing to the baseline (11.79±1.87,12.39±2.35,14.05±2.15;F=4.212, t values:-4.619,-0.989, all P<0.05).Number of myocardial perfusion/metabolic abnormal segments in group 2 after 1 month treatment was lower comparing to the baseline and 24 months treatment (10.17±0.66, 12.92±0.99, 14.17±1.21;F=3.543, t values:-2.146,-2.898, all P<0.05).The PSI, mismatched segments and K values post-treatment were not significantly different between group 1 and 3 (F values: 0.093-1.364, all P>0.05).Conclusions Multi-modality imaging may be used for accurately detecting abnormal myocardium and predicting prognosis.CABG+BMSC therapy during day 4-14 post-MI may temporarily improve perfusion and metabolism in viable myocardium, but the long term prognosis seemed not be improved.