Multi-level Ponte Osteotomies Combined with Four-Rods Compression in Correcting Scheuermann's Kyphosis

孙旭,陈曦,陈忠辉,李松,王斌,朱泽章,钱邦平,邱勇
DOI: https://doi.org/10.3760/cma.j.issn.0253-2352.2017.03.001
2017-01-01
Abstract:Objective To assess the effectiveness of multi-level Ponte osteotomies combined with four-rods compression in correcting Scheuermann's kyphosis (SK) via a posterior approach.Methods We retrospectively reviewed a consecutive cohort of 17 patients (15 males and 2 females) with SK who were treated with multi-level Ponte osteotomies combined with four-rods compression technique between July 2012 and September 2014.The mean age was 18.1±2.8 years old.Ponte osteotomy was routinely conducted around the apex region.Furthermore,bilateral satellite rods were implanted laterally to the main correction rods.The satellite rods and the main correction rods were collected via dual-head screws bilaterally.Gradual compression was applied by the four-rods complex to obtain maximal correction of kyphosis.The sagittal parameters,including global kyphosis (GK),sagittal vertical axis (SVA),proximal junctional angle (PJA) and distal junctional angle (DJA),were recorded at pre-operation,post-operation and at last follow-up.The MOS item short from health survey (SF-36) was conducted at pre-operation and at each follow-up to evaluate the clinical outcomes.Results The average follow-up duration was 14.9±4.2 (range,13-31) months.The pre-operative and post-operative GK was 66.7°± 14.1° and 28.9°±8.1° respectively,and the mean correction rate of Cobb angle was 56.2%± 11.5%.At the last follow-up,the average GK was 29.4°±9.2°.The average PJA increased from 8.6°±4.2° before surgery to 10.3°± 3.6° after surgery,and to 10.5°±3.9° at the last follow-up.The pre-operative,post-operative and last follow-up DJA were 7.6°± 4.2°,5.3°±3.3° and 5.8°±2.7°,respectively.The pre-operative,post-operative and last follow-up SVA were-20.8±28.1 mm,-16.7±19.5 mm and-12.4±16.5 mm,respectively.No significant correction loss or change in PJA or DJA was observed.Although one screw permeated the upper endplate,there was no neurological complication.The following complications,including correction loss,proximal junctional kyphosis,distal junctional kyphosis,pseudoarthrosis and implant-related complication,were not observed during follow-up.Conclusion Multi-level Ponte osteotomies combined with four-rods compression in correcting SK is effective in dispersing stress of each rod and in achieving satisfied clinical outcomes,as well as maintaining correction of kyphosis and preventing implant-related complications.
What problem does this paper attempt to address?