A Hemodynamic Study of Canine Vertebral-Basilar Artery Aneurysm Models

JIANG Yun-zhao,WANG Qi-hong,LAN Qing,WANG Sheng-zhang,LU Hua,WU Wei-jiang
DOI: https://doi.org/10.3760/cma.j.issn.1001-9030.2012.09.012
2012-01-01
Abstract:Objective To establish canine vertebral-basilar artery aneurysm models and evaluate hemodynamics in the models.Methods Partially anastomose right common carotid artery (CCA) and left CCA (end to side anastomosis) to create inverted Y-junction of arteries,and then suture a harvested segment of external jugular vein to the notch of anastomosis to create a vertebral-basilar artery aneurysm.These animals were examined by using 3D digital subtraction angiography 4 weeks after surgery.Geometry parameters of the aneurysm and surrounding vasculature,specific double inlet profiles were analyzed by simulation of computational fluid dynamics (CFD) on these animal models.Results All 9 aneurysm models were created successfully.Completely patency was observed in 8 cases,partial patency in 1 case.The aneurysm height was (8.83 ±2.61) mm,the width was (5.62±1.38) mm,the neck width was (3.92 ±1.68)mm,and the AR was 1.98 ± 0.53.Geometric and hemodynamic environments created in vertebral-basilar artery aneurysm models are similar to those reported for human vertebrobasilar junction aneurysms.Conclu-sion This study documents possibility and feasibility of creating vertebral-basilar artery aneurysm models in the canine.This model may be useful in preclinical studies targeting various complex vertebral vertebralbasilar artery aneurysm.