Nutrient removal by full-scale Bi-Bio-Selector for nitrogen and phosphorus removal process treating urban domestic sewage at low C/N ratio and low temperature conditions
Donghui Li,Weiguang Li,Kailei Zhang,Guanglin Zhang,Houqiang Zhang,Duoying Zhang,Pengfei Lv,Jiao Wu
DOI: https://doi.org/10.1016/j.psep.2020.05.011
IF: 7.8
2020-01-01
Process Safety and Environmental Protection
Abstract:•Bi-Bio-Selector for nitrogen and phosphorus removal (BBSNP) process was investigated.•The desired effluent quality was achieved by BBSNP at low temperature and low C/N.•High MLSS was a practical way to solve low nitrifying efficiency at low temperature.•DPAOs played significant roles in TN and TP removal at BBSNP process.•Dechloromonas was in higher amount than other DPAOs in the BBSNP process.
What problem does this paper attempt to address?