Circularly Polarized Light to Study Linear Magneto-Optics for Ferrofluids:Θ-Scan Technique
Xiangshen Meng,Yan Huang,Zhenghong He,Yueqiang Lin,Xiaodong Liu,Decai Li,Jian Li,Xiaoyan Qiu
DOI: https://doi.org/10.1088/1361-6501/aab0e2
IF: 2.398
2018-01-01
Measurement Science and Technology
Abstract:Circularly polarized light can be divided into two vertically linearly polarized light beams with +/- pi/2 phase differences. In the presence of an external magnetic field, when circularly polarized light travels through a ferrofluid film, whose thickness is no more than that of lambda/4 plate, magneto-optical, magnetic birefringence and dichroism effects cause the transmitted light to behave as elliptically polarized light. Using angular scan by a continuously rotating polarizer as analyzer, the angular (theta) distribution curve of relative intensity (T) corresponding to elliptically polarized light can be measured. From the T - theta curve having ellipsometry, the parameters such as the ratio of short to long axis, and angular orientation of the long axis to the vertical field direction can be obtained. Thus, magnetic birefringence and dichroism can be probed simultaneously by measuring magneto-optical, positive or negative birefringence and dichroism features from the transmission mode. The proposed method is called theta-scan technique, and can accurately determine sample stability, magnetic field direction, and cancel intrinsic light source ellipticity. This study may be helpful to further research done to ferrofluids and other similar colloidal samples with anisotropic optics.