Correlation Measurement of Co-Located Hydrogen Masers Using Fiber-Based Frequency Synchronization Network

Yichen Guo,Bo Wang,Jingwen Dong,Hongwei Si,Lijun Wang
DOI: https://doi.org/10.33012/2018.15612
2018-01-01
Abstract:The rapid development of high-precision time and frequency transfer techniques allow the real-time comparison of remote hydrogen masers (H-masers). Since the year of 2013, we have been working on building a fiber-based frequency synchronization network in Beijing, using our homemade frequency transfer devices and buried city fiber links. So far, frequency signals of 3 H-masers from 2 different institutes are transferred to our laboratory in Tsinghua University and are compared with the local H-maser in real time, forming up a clock ensemble of 4 clocks from 3 places. Using this frequency network, we studied the correlation of the pair of co-located H-masers. With our measurement we found that the correlation is at the magnitude of 10(-30) and only shows up after the averaging time is larger than 10(3)s.
What problem does this paper attempt to address?