An Optimized 3D Displacement Probe Using Sensitivity-Compliance Joint Model
Weikang Zheng,Zhigang Liu,Xinbo Li,Junkang Guo
DOI: https://doi.org/10.1063/1.5110792
IF: 1.6
2019-01-01
Review of Scientific Instruments
Abstract:The existing analytical methods for 3D probes with the monolithic elastic mechanism are usually one-dimensional or two-dimensional, while the contact force acting on the stylus ball is three-dimensional. The mismatch between the methods and the actual force suppresses the performance optimization of the elastic mechanism. This paper proposes a 3D multivariate-decoupling sensitivity-compliance joint model of a 3D probe with the Hexflex mechanism. The decoupling relationships of the system input, structural parameters, and system output are thus revealed. The key parameters affecting probe performance, namely, output compliance, input compliance, and sensitivity, are obtained through the joint model, which contributes to an optimized mechanism with the same topological configuration with the Hexflex mechanism. Finite element analysis (FEA) shows that the output compliance, input compliance, and sensitivity of the optimized probe are increased by 157.7%, 48.4%, and 78.6%, respectively. The resolution and contact force of the probe are greatly improved. The calibration experiment of the prototype validates the theoretical analysis and FEA, showing significant consistency. Furthermore, this paper analyzes the linearity, repeatability, and measurement deviations of the optimized probe. Compared with the Renishaw probe TP200 and other smaller probes, the probe has better performance in compliance and sensitivity.