Monitoring the disbond of externally bonded CFRP composite strips for rehabilitation of bridges

Qing X. P.,Wu Z.,Chang F. -K.,Ghosh K.,Karbhari V.,Sikorsky C.
2006-01-01
Abstract:Integrated active Structural Health Monitoring (SHM) systems have been developed as nondestructive evaluation tools for detecting the disbonds of externally bonded CFRP composite strips for rehabilitation of bridges. The SHM system includes a built-in sensor network, supporting diagnostic hardware and data processing/analysis software. Two active modes for Structural Health Monitoring are presented in the paper: one is based on piezoelectric actuators and sensors, the other uses hybrid piezoelectric actuators/fiber optic sensors. The piezoelectric actuators and sensors based SHM system was demonstrated on a concrete bridge model in the laboratory. Test results showed that the system could detect the disbonds between the composite strips and the deck slab at different load stages well. The concept of the hybrid SHM system and potential application in the rehabilitation of bridge are described. Meanwhile, the advantages for the two active modes are also discussed.
What problem does this paper attempt to address?