Modeling and Analysis of Doubly Fed Wind Power Generation System

Wang Zhijie,Liu Sanming,Liu Tianyu,Wang Dongwei,Du Bin,Huang Qiyuan,Jiang Xiucheng,Sheng Gehao
DOI: https://doi.org/10.2991/iceep-16.2016.49
2016-01-01
Abstract:In this paper, the steady state and transient model of the DFIG system are analyzed. It is concluded that the PI controller parameters and stator transient current are influenced by different parameters of the system, including resistance value, generator rotor inductance or sag magnitude of power grid voltage, etc. Then the steady state and transient model of doubly fed wind power generation system are analyzed. It is concluded that there are two ways to improve the low voltage operation of the doubly fed wind power generation system. One is to use the optimal control strategy to improve the control of the current inner loop of the doubly fed wind power generation system; The other is that when the power grid voltage has the drop fault, it can be considered to increase the Crowbar protection circuit to consume excess energy in the DC side, this way can solve the problem of high DC bus voltage caused by unbalanced power.
What problem does this paper attempt to address?