Analysis and Practical Determination of Wind-Load Shape Factors for Low-Rise Hip Roofed Buildings
JIAO Yu-feng,CHEN Shui-fu
DOI: https://doi.org/10.3969/j.issn.1007-4708.2007.03.011
2007-01-01
Abstract:Practical formulas for determination of wind-load shape factors on the roof of low-rise hip roofed buildings under different wind directions have been proposed by means of the numerical simulation and wind tunnel test investigation.The basic size of the building under consideration is 7.5 m×15 m in plan,9.6 m of eave height and 1.5 m of overhang length.A boundary layer wind tunnel test was conducted for the building model at a geometric scale of 1∶20 and numerical simulations were carried out for the buildings with various roof pitches of 15°,25°,35°45°and 60°,various height-width ratios of 0.4,1.0,2.0,3.0 and 4.0 and various length-width ratios of 2.0,3.0,4.0,5.0 and 6.0.The obtained numerical results and the corresponding test data(if available) are presented in the paper and compared with each other.The results indicate that the roof pitch and height-width ratio are the main factors influencing the hip roof pressures.Practical formulas for determination of the hip roof shape factors are then proposed.A numerical example showing application of these formulas is finally given and good agreement is reached between the practical determination and wind tunnel test.It demonstrates that the proposed formulas are accurate and directly applicable to wind resistant design of hip roofed buildings.