Analysis of Vibration Isolation for Gibson Ground Using WIB

Guangyun Gao,Bo Zhang,Wei Li
2011-01-01
Abstract:The project on the isolation of man-made vibration is becoming a special concern in the civil and environmental engineering field. The system of wave impedance block(WIB),which is one of the effective countermeasures to isolate the ground vibration, has been gradually applied to the engineering practice. In this paper, the efficiency of vibration isolation for Gibson ground by WIB in a three-dimensional(3D) context is studied. The analysis is accomplished with the aid of a 3D semi analytical boundary element method (BEM) based on thin-layered method (TLM), on which the Green's function is regarded as fundamental solution of a stratified half-space. Then the active isolation effectiveness by WIB is studied in elastic half-space. The paper in detail studied relevant parameters in the design of 3D WIB isolation in Gibson elastic half-space. The results indicated that increasing the thickness and modulus of WIB is the two most effective ways to get a good effect of isolation. And the Gibson ground's properties have some influence on the effect of isolation. Moreover,increasing the diameter of WIB can obviously diminish the amplitude of ground vibration around the WIB,while the effect of WIB on outside ones is more complex.
What problem does this paper attempt to address?