Screening method for xanthine oxidase inhibitor screen printed electrode

Zhou Juan,Liu Min,Ding Hong
DOI: https://doi.org/10.3321/j.issn:0567-7351.2008.08.028
2008-01-01
Acta Chimica Sinica
Abstract:To establish a new screening method for xanthine oxidase inhibitor using screen printed electrode the one-off screen printed carbon paste electrode was prepared using screen printing technology. Carboxylic multi-walled carbon nanotubes were absorbed on the working surface of the screen printed electrode. This is a simple and rapid amperometry analysis method of uric acid determination which was applied to xanthine oxidase inhibitor screening in vitro. A sensitive response was obtained at an applied potential of 0.3 V vs. Ag/AgCl. The response time is 30 s. A linear response to uric acid was obtained up to 300 mu mol.L-1 with a limit of detection of 1 mu mol.L-1. The linear regression equation is Y = 43.8240X-0.1592 (r = 0.9998). The analysis was applied to four kinds of water extracts of traditional Chinese medicine. The group of Laranthus tanakae with a concentration of 500 mu g.mL(-1) is significantly different from the control group. The method is simple and rapid with low manufacturing costs of the electrode and a simple apparatus.
What problem does this paper attempt to address?