Frequency Instability of a Miniature Optically Pumped Cesium-Beam Atomic Frequency Standard

Weibin Xie,Qing Wang,Xuan He,Nan Chen,Zezheng Xiong,Shengwei Fang,Xianghui Qi,Xuzong Chen
DOI: https://doi.org/10.1063/5.0001749
2020-01-01
Abstract:This paper proposes a miniature optically pumped cesium-beam atomic frequency standard with a volume of 38.4 l and a weight of 28 kg and examines the main factors that affect its signal-to-noise ratio (SNR). Methods to improve the SNR are proposed, which improve the short-term frequency instability: installing a collimator at the exit of the cesium oven, using the beam fluorescence spectrum with the fiber-coupled output to stabilize the laser frequency, and using the 4-5 cycling transition of the cesium D2 line for the atomic detection. We also examine several frequency shifts that affect the long-term frequency instability and detail methods to reduce these shifts. At present, the frequency instability achieved by the Peking University miniature optically pumped cesium-beam frequency standard has reached 3.12×10-12/τ.
What problem does this paper attempt to address?