Study on alloy compensation approach based on energy spectrum equivalent method

Xiao-Min Zhang,Zhi-Fang Wu
DOI: https://doi.org/10.7538/yzk.2016.50.09.1688
2016-01-01
Abstract:Aiming at the problem on alloy compensation in X‐ray thickness measure‐ment ,based on the energy spectrum equivalent method ,according to the one‐to‐one mapping between alloy compensation coefficient and the energy of single energy ray ,and also the mapping between alloy compensation coefficient and thickness of material in the continuous spectrum , an approach transforming the problem of X‐ray continuous spectrum into single energy gamma ray was worked out by comparing the alloy compen‐sation coefficients .A concrete proposal including system calibration ,thickness calibra‐tion ,energy calibration and energy spectrum equivalent was proposed .An X‐ray thick‐ness measurement simulation model built by Monte Carlo program was established .And the simulation model was used to verify the energy spectrum equivalent result .The results show that the relative errors of thickness measurement compensated by the energy spectrum equivalent for above 90% of alloys are less than 0.1% .It indicates that the alloy compensation approach is practical and it can be used in many fields . T he energy spectrum equivalent is reference for studying the hardening of X‐ray continuous spectrum .
What problem does this paper attempt to address?