A Novel Stray Inductance Extraction Method for Bus Bars Based on Turn-on/off Transient Process

FENG Gaohui,YUAN Liqiang,ZHAO Zhengming,ZHAO Jincheng,LU Ting
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2014.36.009
2014-01-01
Abstract:In the turn-off transient of a switch device, the combined action of stray inductance in the converter circuit and the di/dt can bring higher voltage peak in the turn-off transient than in the off state, can result in more electric stress, and can increase switching losses and EMI. The stray inductance also produces a great deal of harmonics and influences inverter performance. Thus, as the most critical component, the bus bar stray inductance needs to be calculated accurately in converter circuits. In the base of analyzing the merits and faults of several existed methods for stray inductance extraction, the paper analyses multiple stages of turn-on/off transient and finds the best stage for inductance extraction. Then, it provides an integral arithmetic method in turn-on process to replace the differential arithmetic in turn-off process. In the actual large capacity inverter, which is composed by 3.3kV/1200A IGBT module, the stray inductance is extracted by the new method, and the results are compared with PEEC analysis results. The accuracy and practicability of the new extraction method are verified by the comparison.
What problem does this paper attempt to address?