Partial Discharge Characteristics of Electrical Tree Growth in Silicone Rubber

Chen Jie,Zhou Li,Zhou Yuanxiang,Zhang Yunxiao
DOI: https://doi.org/10.16790/j.cnki.1009-9239.im.2017.03.016
2017-01-01
Abstract:The electrical tree growth and partial discharge characteristics of silicone rubber for cable acces-sories were studied, and the PD characteristics under different electrical tree growth stages were summa-rized. The results show that the typical growth pattern of electrical tree mainly contains growth-retarda-tion pattern and growth-breakdown pattern, and the former mostly presents in bush-like trees, while the latter mostly presents in pine-like and branch-like trees. The electrical tree growing process includes tree initiation stage, tree growing stage, growing retardation stage, and breakdown stage. Different electrical tree growth stages have different PD characteristics, which provide helpful information to the power cable on-line monitoring.
What problem does this paper attempt to address?