Cone-beam reconstruction for the 2-circles plus line trajectory

Yanbin Lu,Jiansheng Yang,John W. Emerson,Heng Mao,Yuanzheng Si,Ming Jiang
2011-01-01
Abstract:The 2-circles plus lines trajectory is designed to solve the problem of limited physical space in a multimodality imaging system for the introduction of X-ray cone-beam CT. We apply the backprojection filtration algorithm proposed by Pack et al for X-ray cone-beam data to the standard 2-circles plus lines trajectory. We find that for every point inside the region between the two circles there exists at least one redundantly measured line (a line segment that connects two sources points, R-line), and so the region can be fully covered by R-lines. Furthermore, for about 2/3 of the points inside the region there exist two or more such R-lines. The length of the line curve segment required by the algorithm can be as short as the distance between the two circles when the projections have no truncation. Numerical simulations validate the feasibility of the algorithm and the spiral resolution of cone-beam CT in the imaging system.
What problem does this paper attempt to address?