A numerical study of pulsatile microflows for embryo culturing in microfluidics

Jiaming Shi,Jun Dong,Huaying Chen,Yijuan Sun,Xiaoxi Sun,Yonggang Zhu
2018-01-01
Abstract:An embryo is subject to dynamic mechanical stimuli exerted by a fallopian tube before implantation, which may include shear stress, compression and friction. The mechanical microenvironment plays vital role in the early development of an embryo. In addition, the oviduct fluid is flowing in a pulsatile manner with a certain frequency, rather than constant. The purpose of this study is to simulate the mechanical stimulation of the oviduct fluid on an embryo, in order to model the mechanical microenvironment of an embryo in vitro. In this simulation, a rigid bead with the diameter of 300 microns was used to represent the embryo placed in three different sites on the floor of a microchamber with the diameter of 1 mm. A pulsatile flow with the average velocity of V=2.4×sin(2πt/7.4) + 2.5 (μm/s) was set up at the inlet port. The numerical study shows that the shear stress is also change with time and it’s the same trend with velocity. In addition, the maximum shear stress appears at the junction of the culture dish and the outlet channel and it is 2.7×10 dyn/cm, which is close to the shear stress experienced by mouse embryos in the fallopian tubes.
What problem does this paper attempt to address?