Study on discharge character of 200 W Hall thruster with metal wall IEPC-2017-159

Yongjie Ding,Yizhou Zhang,Wuji Peng,Liqiu Wei
2017-01-01
Abstract:One 200W annular channel permanent magnet Hall thruster was designed. The magnetic field intensity of section of channel outlet at pitch diameter position is 80% of the maximum magnetic field. An integrated structure of U-shaped shrunk anode/gas distributor is adopted, the whole discharge channel is made of Ti metal, and the channel and the anode are insulated by using BN ceramic. Under the conditions that the anode mass flow is 1, 1.1, 1.2 and 1.3mg/s, the voltage is 150-400V at the interval of 50V, and the power is 118488W, the discharge properties of the condition under which the channel and shell are insulated or conductive are respectively tested, the results show that when the channel is insulated from the shell, the thrust is 6.2-22.2mN, the specific impulse is 635-1748s, the anode efficiency is 16.3-39.2%, which are slightly higher than the thrust, the specific impulse and the anode efficiency under the condition that the channel is conducted with the shell, and in addition, the potential of the channel and the shell is within 30-90V, which is related to discharge situation.