Magnetic-Resonance Analysis of Dynamic Permeability Change in Focused-Ultrasound Induced Blood-Brain Barrier Disruption in Small Animals

Wen-Yen Chai,Po-Chun Chu,Yu-Chun Lin,Jiun-Jie Wang,Yau-Yau Wai,Tzu-Chen Yen,Hao-Li Liu
2011-01-01
Abstract:Introduction Microbubble-enhanced burst-mode focused ultrasound (FUS) has been reported to be able to transiently and locally disrupt the blood-brain barrier (BBB), which opens a wide spectrum of opportunity for delivering therapeutic agent into the brain [1]. Magnetic resonance imaging has been recognized to serve as a post-operational evaluation tools for evaluate BBB disruption, such as the use of dynamic contrast-enhanced MRI (DCE-MRI) to identify BBB-disrupted region. Besides of DCE-MRI, MR perfusion/permeability analysis may also provide valuable information to explore the pharmacokinetics/pharmacodynamics (PK/PD) of the delivered drugs of this approach. This may be particularly essential when FUS-induced BBB disruption only sustained for a limited duration (usually a few hours) and the permeability during this period is highly dynamic. The purpose of this study is to evaluate perfusion/permeability change in the FUS-induced BBB disruption process. Material and method Six Sprague-Dawley Rats of either age (300±25g) were used in this study. Each Rat was under isoflurane anesthesia first. A spherically focused ultrasound transducer (400 kHz, diameter/curvature radius = 60/80 mm) was used to transcranially sonicate one hemisphere of rat (peak pressure = 0.4MPa, burst length = 10 ms, PRF = 1 Hz, duration = 90s) in the presence of microbubbles (Sonovue, Bracco; 0.025 mL/kg IV injection). After sonication, animals were immediately moved to MR bore and conducted post-operational MRI scan (7T, ClinScan 70/30 USR, Bruker) for 10 mins. immediately with bolus injection of gadolinium-based MR contrast agent from tail vein (Agnevist, Bayer Healthcare, 0.5ml/kg). Two Dynamic susceptibility-contrast (DSC)-MRI were acquired at 10/150 mins. after BBB-disruption (3D FLASH T1-weighted sequence, TE/TR = 0.76 ms/ 2.31 ms; slice thickness = 0.8 mm; flip angles = 5°/20°; matrix size:192×132). Perfusion/permeability information were obtained based on data post analysis using the Extended-Kety model [2] to generate permeability information including the Ktrans (represents vessel permeability change) and Ve (represents extravascular-extracellular space change) map. ROIs of Ktrans and Ve maps obtained from experimental and contralateral brains were selected for statistic analysis. Result/ Discussion A representative images sets showing the Ktrans/ Ve distribution was demonstrated (Fig. 1a-1d).The dynamic change of Ktrans/ Ve can be demonstrated when comparing Ktrans/ Ve maps acquired at 10 and 150 min. Both Ktrans and Ve presents a local enhancement at the BBB-disrupted site when compared to the right hemisphere, implies that both vessel permeability and extravascular-extracellular space were altered. Distribution of local Ktrans/ Ve differed, also implies that the local vessel permeability and extravascular-extracellular space change were heterogeneous and independent, and may depend on the vessel/ extravascular space volume fraction difference. When observing at 150 min. after FUS sonicaiton, both Ktrans/ Ve change at the BBB-disrupted region dropped apparently. The mean Ktrans values at the target ROI at 10/150 mins. were 4.2×10 /1.7×10 , showing a decrease about 60%; the mean Ve value of at the target ROI were 2.58×10 /0.9×10 and was also decrease 64%. This implies the local permeability change induced from FUS-induced BBB-disruption were highly dynamic. Conclusion Our results provide evidence that FUS-induced BBB disruption induce dynamic perfusion/ permeability increase within a limited time period (> 60% within 150 min). This information also provides useful insights that an optimal drug-delivering procedure should be design to meet the limited high-permeability change window in the focused-ultrasound induced brain drug delivery.
What problem does this paper attempt to address?