Modeling the Influence of Building Structure on Indoor PM 2 5 Mass Concentration Due to Infiltration

Chao CHEN,Ziguang CHEN,Yuqin WU,Shen WEI,Ping WANG
DOI: https://doi.org/10.13198/j.issn.1001-6929.2017.03.17
2017-01-01
Abstract:Fine particulate matter, generally known as PM2.5 ;has great impact on air quality and human health. Although closing external windows can help prevent outdoor PM2.5 form going indoors, many studies have shown that a significant number of particles can still pass through the building fa?ade through the cracks around the window. In order to quantify the influence of external window crack characteristic and relevant parameters ( such as room dimension) on the indoor ρ( PM2.5 ) ;a longitudinal study monitoring outdoor ρ( PM2.5 ) ;indoorρ( PM2.5 ) and important outdoor meteorological parameters was carried out in six offices located in the Dongcheng and Chaoyang District in Beijing, China. In addition, a model was developed from an existing model developed by the authors, based on two-month field-measured data from five unoccupied offices located in the central area of Beijing, and was then validated against a new dataset measured at another sampling site. In this model, a comprehensive structure characteristic coefficient, AP ;was adopted to reflect the influence of external window crack structure and room dimension. Further, this study adopted a method that can be used to calculate the value of Ak based on the building's external window crack structure and room dimension, which are easier to be obtained. The model is capable of quantifying indoor ρ( PM2.5 ) based on instant outdoor ρ( PM2.5 ) ;with consideration of impact from external window crack characteristics, room dimension and outdoor meteorological conditions, i. e. outdoor wind speed and relative humidity. The model was validated by measurement data. The prediction results showed that under the same outdoor conditions, such asρ( PM2.5 ) and temperature, indoor air quality forρ( PM2.5 ) was significantly affected by external window crack structure. The I∕O ratio〔the ratio between indoorρ( PM2.5 ) and outdoorρ( PM2.5 )〕 was generally within 0. 4 and 0. 7. Additionally, when increasing the window crack height by 50% or the window crack depth by 50%, the corresponding I∕O could be decreased by 33. 6% and 31. 9% respectively. The study shows that narrower window crack height and deeper window crack depth with higher window air-tightness can control indoorρ( PM2.5 ) well under the condition of infiltration.
What problem does this paper attempt to address?