Pulsed Ultrasonic Wave Assisted GMAW of 7 A 52 Aluminum Alloy

W. F. XIE,C. L. FAN,C. L. YANG,S. B. LIN
IF: 2.2
2016-01-01
Welding Journal
Abstract:As a new welding process, pulsed ultrasonic­wave­assisted gas metal arc welding (PU­GMAW) was first proposed. The peak power output of pulsed ultrasonic is higher than that of continuous ultrasonic. In theory, the effect of ultrasonic treatment on the molten metal should be more pronounced during the welding process. To prove the fea­ sibility of this idea, three groups of comparative experiments, including gas metal arc (GMA), continuous ultrasonic­wave­assisted GMAW (U­GMAW), and PU­GMAW of 7A52 aluminum alloy were conducted. A high­speed camera and a spectrometer were employed to detect the welding process in real time. The weldments were evaluated by performing a variety of testing methods. In PU­GMAW, when the smallest droplet size and the largest metal transfer frequency were obtained, the weld area increased signifi­ cantly. The grains refined by pulsed ultrasonic were much finer than those refined by continuous ultrasonic. The microhardness tests revealed the degree of softening of the joint decreased. The microstructure and element analysis showed the presence of the coarse second­phase particles, which was a cause of softening in the fusion zone, and due to enhanced ultrasonic agitation there was a significant inhibitory effect to the Zn el­ ement gasification loss. Compared with the ultimate tensile strength (UTS) and elongation of the GMA joint, those of the PU­GMA joint increased 23 and 62%, respectively. The UTS and elongation of the U­GMA joint were 8.34 and 15.43% lower than those of PU­GMA joint, respectively.
What problem does this paper attempt to address?