fMRI Gets BOLD er at High Fields

Xiaoping Hu
2006-01-01
Abstract:The majority of fMRI experiments are conducted based on the blood oxygenation level dependent (BOLD) contrast [1-3], which is derived from the fact that deoxyhemoglobin is paramagnetic while oxyhemoglobin, similar to tissue, is diamagnetic, and changes in the local concentration of deoxyhemoglobin in the brain lead to alterations in the MRI image intensity. It is generally accepted that neuronal activation induces an increase in regional blood flow without a commensurate increase in the regional oxygen consumption rate (CMRO 2) [4-6]. Consequently, local capillary and venous deoxyhemoglobin concentrations decrease during neuronal activation, leading to an increase in T 2 * and T 2. This increase is reflected as an elevation of intensity in T 2 *-and T 2-weighted MR images. Based on this principle, to map neuronal function, T 2 * (or T 2) – weighted images are acquired consecutively while the subject either rests or performs certain task or is presented with certain stimuli. These images are subsequently analyzed with statistical methods to ascertain regions exhibiting significant signal changes between the task performance/stimulation and resting periods. For fMRI based on the BOLD contrast, high magnetic fields are very desirable because, as discussed below, both the sensitivity and specificity increase with the magnetic field. In fact, the desire to improve the sensitivity and specificity of fMRI has been a major force driving the move towards higher and higher magnetic fields for in vivo MR. It is generally accepted that the signal-to-noise ratio (SNR) in MR images scales linearly with the field strength [7] and this view is experimentally demonstrated to the field strength as high as 7 T although the B1 field and hence the coil sensitivity become somewhat nonuniform at very high magnetic fields [8]. In addition to the increase in SNR, theoretical considerations indicate that the BOLD contrast increases supralinearly with the field strength, depending on contributions from static and dynamic averaging [9]. The effect of the BOLD field inhomogeneity on the MR signal has been discussed extensively by others [9, 10] and is briefly summarized here. In the brain, hemoglobin stays within blood vessels and its effect on water protons depend on the location of the protons relative to the blood vessel. For the extravascular (i.e., tissue) spins, there is the dynamic averaging effect, which arises due to diffusion during the echo time (TE). Because the diffusion distance within typical TE is rather small, dynamic averaging is prominent …
What problem does this paper attempt to address?