Understanding of high radon concentrations observed in a well-ventilated japanese wooden house

S Tokonami,H Yonehara,W Zhuo,Q. Sun,T Sanada,Y Yamada
2002-01-01
Abstract:Two nation-wide indoor radon surveys have been conducted in Japan. There was a significant difference between the two surveys. The first survey covered over 7000 houses using Karlsruhe passive radon detectors developed in Germany. The first survey provided relatively higher radon concentrations than expected though there are many well-ventilated wooden houses in Japan. The arithmetic mean was estimated to be 20.8 Bq m. In the second survey, on the other hand, it was 15.5 Bq m. In order to understand the inconsistency, passive radon detectors used in the first survey were placed in a traditional room at a Japanese wooden house. The concentration was functioned by the distance from the wall. Although passive radon detectors are designed to detect radon only effectively, a little contamination of thoron was often found in readings obtained from some detectors according to our experimental studies. INDEX TERMS Radon, Thoron, Ventilation, Soil wall. INTRODUCTION Many countries have experienced the nationwide indoor radon survey based on their social requirements. The indoor radon problem is still a large concern all over the world from the viewpoint of radiation protection research. This matter is supported by the fact that radon progeny inhalation makes a large contribution to radiation dose for general public. On the other hand, a lot of problems remain unsolved on the dose assessment due to radon. There is a difference on the estimate between two approaches for dose assessment: a dosimetric approach and an epidemiological approach. It has been pointed out that they differ by the factor of around 3. Various matters should be discussed so as to minimize the gap. More epidemiological studies should be conducted in naturally high background areas. In the epidemiological estimate, a long-term radon exposure is required. A passive radon detector is suitable for that purpose. However, a special attention must be accordingly paid to the presence of thoron. The presence of thoron has been ignored so far because its quantity is considered to be small. For more accurate dose assessment, however, radon concentration should be precisely estimated even though the thoron concentration is low. *Contact author email: tokonami@nirs.go.jp Proceedings: Indoor Air 2002
What problem does this paper attempt to address?