Experimental Investigation of Transpiration Cooling With Phase Change in High Temperature Flow

Gan HUANG,Zhi-Yuan LIAO,Yin-Hai ZHU,Zheng HUANG,Pei-Xue JIANG
2017-01-01
Abstract:Transpiration cooing with phase change is important for the thermal protection of the key components of hypersonic vehicles.The transpiration cooling for sintered porous bronze plate using liquid water as the coolant was experimentally investigated in the mainstream with a temperature of 700 K in this study.The experimental results showed that the efficiency of transpiration cooling with phase change was very high.There are obvious relative high temperature zone and well cooled zone on the porous plate surface at certain range of coolant injection ratio due to the vapor blockage effect.The boundary between the obvious relative high temperature zone and well cooled zone oscillated periodically.The transpiration cooling efficiency increased with properly reducing the particle diameter of the sintered porous plate.
What problem does this paper attempt to address?