Research of Boiler Slagging Real-time Monitoring System based on Micro Heat Flow Meter

Ji-lu GAO,Xiao-li CHEN,Jian-xun DONG,Kai-yu PANG,Min ZHANG,Yu-xin WU
DOI: https://doi.org/10.3969/j.issn.1002-6339.2018.02.002
2018-01-01
Abstract:Boiler slag will reduce the water wall and convection heating surface heat transfer efficiency,seriously affecting the normal operation of the boiler.In order to achieve a large proportion of the boiler mixed with easy to slag the quasi-east coal,an urgent need to accurately detect the degree of slagging furnace industrial devices and automated control system to ensure the safe operation of the boiler.In this paper,a one-dimensional thermal model is established to study the effect of different parameters on the response time of the heat flow meter.The results show that the heat flow meter is sensitive to heat flow and the response time is about 30 s,which satisfies the slagging monitoring requirements.Based on the temperature difference method,ultrafine high temperature heat flow meter,on the basis of the development of a micro heat flow meter based on the water wall slagging real-time monitoring system,and a thermal power plant in Jilin province conducted a field test.The field test results show that the device can accurately measure the heat flux density without damaging the boiler water wall,and also prove the feasibility and reliability of the system to predict the degree of slagging.
What problem does this paper attempt to address?