The Distribution of Levels of Disinfection By-products in Drinking Water
魏建荣,王振刚,郭新彪,姜丽娟,李焕如,江姜,曾迎,朱志勤,李键
DOI: https://doi.org/10.3969/j.issn.1001-5914.2004.01.012
2004-01-01
Abstract:Objective To explore the distribution of the concentrations of disinfection by-products (DBPs) and its characteristics in drinking water. Methods The levels of DBPs in the finished water samples and source water samples collected from 15 water works in a certain city were analyzed. 17 compounds of DBPs classified into 6 fraction including trihalomethames (THMs), halogenated acetonitriles (HANs), chlorinated acetic acids (HAAs), halogenated ketones (HKs), chloral hydrate (CH), chloropicrin (CP), in the water samples were determined. Some indexes related with the formation of DBPs including total organic carbon, pH value, residual chlorine, water temperature and contact time for disinfection were determined simultaneously. Results THMs and HANs were the two major fraction of DBPs in the finished water samples, which accounted for 42.6% and 38.1% (weight/weight) of all DBPs measured out respectively. The others of the DBPs measured out were HANs, CH, HKs, and CP, which accounted for 8%, 7%, 2.9% and 1.4% of all the DBPs measured out respectively. The DBPs concentrations in source water samples were very low, each of the 6 fractions of DBPs showed the average levels of 0.06~1.97 μg/L. The concentrations of various fraction of DBPs measured out in chlorinated finished water increased in different degrees. THMs and HAAs showed average concentrations of 10.7 μg/L and 8.88 μg/L, maximum concentrations of 21.1 μg/L and 20.9 μg/L in the chlorinated finished water respectively, which increased by 6.1 times and 3.6 times averagely compared with those in source water respectively, they were almost found in finished water samples from water works supplied by simple surface water source and mixed water source of surface water and ground water source. Chloroform (TCM), bromodichloromethane (BDCM), dichloroacetic acid (DCAA), trichloroscetic acid (TCAA) were the major fraction among 17 compounds of DBPs found in all water samples. The levels of BDCM in finished water were higher than those of TCM. There was a strong positive correlation between levels of DBPs and the parameters such as TOC, water temperature and contact time for disinfection, and a weak positive correlation between levels of DBPs and concentrations of residual chlorine and pH values.Conclusion 17 compounds of DBPs with different concentrations were found in finished water and source water, and variated with the different qualities of drinking water. The distribution of DBPs levels in drinking water was variated with the various kinds of water source and presented the following order: simple surface-water source mixed water source ground water source: finished water source water.