Poster Abstract: Robust Calibration for Low-Cost Air Quality Sensors Using Historical Data

Guodong Li,Xinyu Liu,Zhiyuan Wu,Yue Wang,Lin Zhang
DOI: https://doi.org/10.1109/ipsn48710.2020.00-12
2020-01-01
Abstract:As pollution problems become increasingly prominent nowadays, urban air quality monitoring has attracted more and more attention. In recent years, sensing systems based on low-cost sensors are proposed to achieve fine-grained monitoring with larger amount of deployment as supplyment to conventional monitoring stations. Calibration is critical to guarantee the accuracy and consistency of these sensing systems to fight against sensor drift. While conventional field calibration approaches often rely on real-time data from a nearby standard station, they are not applicable to low-cost sensors which cannot receive the latest reference data from nearby stations after deployment. In reality, it is very difficult for sensors to get access to nearby standard stations deployed sparsely. To reduce the dependency on real-time and nearby reference data, we present a Robust Calibration approach based on Historical data (RCH) for the low-cost air pollution sensor calibration. Our method corrects the sensor drift by adapting sensitivity and offset based on estimating the probability distribution of pollutant's concentration. Experiments with real-world NO 2 data in Foshan, China show that our proposed method acheives close performance to conventional field calibration methods but addresses above challenges. Moreover, our method can use historical data collected from the sensors in more distant geographic locations than the compared method.
What problem does this paper attempt to address?