Ion mobility-tandem mass spectrometry of mucin-type O-glycans

Leïla Bechtella,Jin Chunsheng,Kerstin Fentker,Güney R. Ertürk,Marc Safferthal,Łukasz Polewski,Michael Götze,Simon Y. Graeber,Gaël M. Vos,Weston B. Struwe,Marcus A. Mall,Philipp Mertins,Niclas G. Karlsson,Kevin Pagel
DOI: https://doi.org/10.1038/s41467-024-46825-4
IF: 16.6
2024-03-23
Nature Communications
Abstract:Abstract The dense O -glycosylation of mucins plays an important role in the defensive properties of the mucus hydrogel. Aberrant glycosylation is often correlated with inflammation and pathology such as COPD, cancer, and Crohn’s disease. The inherent complexity of glycans and the diversity in the O -core structure constitute fundamental challenges for the analysis of mucin-type O -glycans. Due to coexistence of multiple isomers, multidimensional workflows such as LC-MS are required. To separate the highly polar carbohydrates, porous graphitized carbon is often used as a stationary phase. However, LC-MS workflows are time-consuming and lack reproducibility. Here we present a rapid alternative for separating and identifying O -glycans released from mucins based on trapped ion mobility mass spectrometry. Compared to established LC-MS, the acquisition time is reduced from an hour to two minutes. To test the validity, the developed workflow was applied to sputum samples from cystic fibrosis patients to map O -glycosylation features associated with disease.
multidisciplinary sciences
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to improve the efficiency and accuracy of the structural analysis of mucin - type O - glycans. Specifically, the paper introduces a method based on Trapped Ion Mobility Spectrometry (TIMS) for separating and identifying O - glycan isomers released from mucin. Compared with the traditional Liquid Chromatography - Mass Spectrometry (LC - MS) method, this method has the following advantages: 1. **Significantly shortened analysis time**: The traditional LC - MS method takes about one hour to complete the analysis, while the TIMS method only needs two minutes to obtain a detailed O - glycan profile. 2. **Higher resolution**: TIMS shows higher resolution in separating O - glycan isomers and can more effectively distinguish molecules with similar structures. 3. **Direct provision of structural information**: By measuring the Collision Cross Section (CCS), TIMS can directly provide information about the molecular structure, which helps to more accurately identify the isomers of O - glycans. 4. **High - throughput analysis**: Combining the short analysis time and the diagnostic CCS values, the TIMS method can achieve high - throughput analysis of O - glycan characteristics in clinical samples. To verify the effectiveness of this method, the researchers applied it to sputum samples from patients with Cystic Fibrosis (CF) to map the O - glycosylation characteristics related to the disease. The results showed that the TIMS method can effectively distinguish sputum samples from healthy people and CF patients, and revealed significant changes in O - glycans in the sputum of CF patients, such as the simplification of sugar chain structures and the increase in sialylation. In conclusion, this paper aims to overcome the challenges faced by existing technologies in analyzing O - glycan isomers in complex biological samples by developing a fast, efficient and accurate TIMS method.