Effect of Load on Biomechanical Characteristics During A Step-up Activity
Zhengyan Tang,Jingmin Liu,Xiangrong Cheng,Xia Bai,Peng Lu
DOI: https://doi.org/10.1249/01.mss.0000880576.34239.32
2022-01-01
Abstract:The step-up activity (stair-ascending) is an important daily function. In this process, different weight loads can change the gait characteristics of the human body. However, in the step-up activity, the influence of different loads on human gait is not clear. PURPOSE:To compares the effects of different loads on the gait of the human body in the step-up activity. METHODS:10 male subjects were selected. Age range: 23-26 years old; height: 176.6 ± 5.0 cm; weight: 71 ± 8.3 kg. The load weight is no load, 15 kg, and 30 kg respectively. The load was put on the subjects in the form of weight-bearing vests, the test was carried out on a 30 cm high step, and the subjects walked 15 steps continuously at a frequency of 90 times/min. The gait indexes were collected by the pedar-x plantar pressure test system. SPSS 22.0 was used to process the analysis data, and one-way ANOVA was used to compare the differences of each index under different loads. RESULTS:In the step-up activity, with the increase of load, the peak force of foot and the impulse increased, and there was a very significant difference (peak force, no load: 585.4 ± 108.1 N, 15 kg load: 726.6 ± 113.3 N, 30 kg load: 802.4 ± 124.4 N, P < 0.01; peak impulse, no load: 242.7 ± 44.6Ns, 15 kg load: 317.4 ± 82.5Ns, 30 kg load: 380.7 ± 95.5Ns, P < 0.01). Plantar pressure also increased significantly, but the difference was relatively small (peak pressure, no load: 196.4 ± 45.6 kPa, 15 kg load: 226.1 ± 44.8 kPa, 30 kg load: 240.6 ± 57.9 kPa, P = 0.149). The maximum contact area between the foot and the ground increases with the increase of load, but the difference is not significant (maximum contact area, no load: 113.8 ± 17.0 cm2, 15 kg load: 121.5 ± 19.3 cm2, 30 kg load: 130.0 ± 17.2 cm2, P = 0.146). There was no significant difference in the support phase time and single step gait cycle time (support time, no load: 0.628 ± 0.060 s, 15 kg load: 0.639 ± 0.103 s, 30 kg load: 0.650 ± 0.105 s, P = 0.874; gait cycle time, no load: 1.049 ± 0.076 s, 15 kg load: 1.055 ± 0.072 s, 30 kg load: 1.043 ± 0.087 s ,P = 0.941). CONCLUSIONS:1) In the step-up activity, the increase of load will lead to a significant increase of foot pressure peak and impulse.2) Load does not change the gait time index during a step-up activity. Research supported by the Education Social Science Foundation Project of the 13th Five-Year Plan of Education in China (BLA180218).