Effective restrained radius of confined concrete

Jianguo Nie,Yu Bai,Shengyong Li,Yan Xiao
DOI: https://doi.org/10.3321/j.issn:1000-0054.2005.03.005
2005-01-01
Abstract:Three-axis compression increases the ductility and strength of confined concrete structrues. The radial confined stress is distributed non-uniformly along the radial direction in a limited region, so the area outside this region does not need to be considered. A theoretical model and finite element analyses were used to calculate the effective restrained radius of a confined area, in which the ratio of outside and inside diameters is less than 3. The area is in good agreement with experimental results of local compression test in concrete structures. The method can also be applied to other kinds of confined concrete structures.
What problem does this paper attempt to address?