Frequency band variance and energy operator for bearing fault diagnosis in nuclear power plant

Yuan Chang,Chunwen Li,Xiaojin Huang
DOI: https://doi.org/10.7538/yzk.2014.48.08.1458
2014-01-01
Abstract:By on-line monitoring the equipments in nuclear power plant (NPP) ,their working conditions could be known timely and the faults could be predicted ,so that the safety and economy of NPP can be improved .The monitoring and diagnosis of bearing faults in rotatory machines in NPP were studied . The energy operator method was adopted for the envelope demodulation of the vibration signals , w hich could find the fault characteristic frequencies from the noises and modulating signals .To automatically determine the center frequency of the band-pass filter ,the frequency band variance was proposed as an index ,w hich achieved the maximum around the resonant frequency .T he feasibility and validity of the proposed method were verified by the experimental data . The results show that the conditions of the bearings are effectively monitored ,and fault types are correctly diagnosed.
What problem does this paper attempt to address?