Emission factors test and pollutant discharge of raw coal fuel burning in Beijing countryside

Guowei CHEN,Ming SHAN,Jiarong LI,Jianyun JIANG,Jiandong YE,Xudong YANG
DOI: https://doi.org/10.12030/j.cjee.201708026
2018-01-01
Abstract:Emission factors testing system of pollutant discharge was designed for coal stoves in rural area.Calculation method was established with carbon balance theory.We chose 12 raw coal samples from Yanqing,Fangshan,Pinggu and Huairou districts in Beijing,China.We also chose 10 coal stoves and 3 honeycomb briquette stoves to test the pollutant emission,calculated the emission factors.The result shows the bad raw coal has the highest emission factor of PM2.5 (3.73 g · kg-1) and SO2 (1.78 g · kg-1).The PM2.5 emission factor of good raw coal and ball coal is 3.33 g · kg-1 and 2.20 g · kg-1 But the good raw coal has the lowest SO2 emission factor(0.16 g · kg-1) and the highest NOx emission factor(2.99 g · kg-1).When the heat efficiency is considered,the PM2.5 emission factor of good raw coal and ball coal declines with 12.9% and 8.4% compared with the bad raw coal.The SO2 emission factor declines with 91.2% and 73.8%.While the NOx emission factor of the good raw coal increases with 42.3%.And then,using our survey data,we get the pollutant discharge amount of coal fuel used in Beijing countryside,the result is 18.4 thousand ton and it contributes 11.2% to 16.3% of local pollutant discharge.