Abstract:In view of the imperfection of present efficiency region of multi-split air conditioning system based on energy efficiency ratio at nominal working condition, a concept and a determination method of seasonal efficiency region of multi-split air conditioning system based on seasonal energy efficiency ( SEER) and annual performance factor ( APF) were proposed. The construction approaches of full condition performance models of multi-split air conditioning system and air-cooled water chiller & heater unit plus fan-coil air conditioning system based on experimental data were illustrated. Using the building load model and air conditioning hours at various temperatures in cooling and heating season in GB/T 18837 ( draft for approval) , the seasonal efficiency region of multi-split air conditioning system with different nominal energy efficiency ratio ( EER and COP) in office building in Nanjing was calculated as an application example. The proposed con-cept and determination method of seasonal efficiency region of multi-split air conditioning system can not only provide an option to improve the code for engineering design of multi-split air conditioning system, but also offer guidance for the selection of air conditioning system and equipment in a practical project.
What problem does this paper attempt to address?