Person to person airborne particles cross transmission in vertical laminar air flow room

Caiqing Yang,Xudong Yang,Bin Zhao
2014-01-01
Abstract:Infection is a major cause of death for the immunocompromised patients whose immune mechanisms are deficient or compromised. The most sophisticated of these regimens is the total protected environment such as vertical laminar airflow room. The study of the airborne particle cross transmission from person to person can help to reduce the infection risk for these patients. In this study, we applied computational fluid dynamics (CFD) method to solve the governing equations of airflow, energy, and dispersion of airborne particles. The scenarios when both the source manikin and the susceptible manikin were standing with 0.2 m, 0.4 m, 0.6 m, 0.8 m, 1.0 m and 1.2 m apart were investigated. The transmission of particles from the source manikin’s body and breathing were simulated. A “human thermal plume affecting zone”(HTPA Zone) was proposed to help analyze the simulation results. The results show that to …
What problem does this paper attempt to address?