N‐Doped Carbon Coated TiC Nanofiber Arrays on Ti‐6Al‐4V for Sensitive Electrochemical Determination of Cr(VI)

Xia Zhao,Zanling Huang,Wanying Zhang,Peipei Li,Fushen Lu,Liangsheng Hu
DOI: https://doi.org/10.1002/elan.202100267
IF: 3.077
2021-07-09
Electroanalysis
Abstract:A sensitive electrochemical sensor for Cr(VI) detection based on N-doped carbon coated TiC nanofiber arrays (TiC@CNx NFAs) is reported. The abundant electrocatalytic active sites contained CNx shell, highly conducting TiC core, and good electrical contact between the TiC@CNx and underlying Ti alloy endow this electrode with the excellent electrochemical sensing properties. The developed electrochemical sensor shows remarkable determination activity towards Cr(VI) with a high sensitivity of 0.88 μA μM<sup>-1</sup> cm<sup>-2</sup>, a low detection limit of 4.0 nM (S/N = 3), a wide linear range from 0.2 to 24.1 μM, good selectivity and anti-interference property.
chemistry, analytical,electrochemistry
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop an efficient, sensitive and economical method for detecting hexavalent chromium (Cr(VI)) in water bodies. Specifically, the researchers designed an electrochemical sensor based on titanium carbide nanofiber arrays coated with nitrogen - doped carbon (TiC@CNx NFAs) for highly sensitive detection of Cr(VI). ### Background Hexavalent chromium (Cr(VI)) is a common heavy - metal pollutant, which is highly toxic and carcinogenic and poses a serious threat to human health and the environment. Therefore, it is particularly important to develop a method that can accurately and efficiently detect trace amounts of Cr(VI) in water bodies. ### Research Objectives 1. **Develop new electrode materials**: Improve the performance of the electrochemical sensor by preparing titanium carbide nanofiber arrays coated with nitrogen - doped carbon (TiC@CNx NFAs). 2. **Improve detection sensitivity and selectivity**: Ensure that the sensor has high sensitivity, a low detection limit and good selectivity when detecting Cr(VI). 3. **Simplify the detection process**: Achieve direct detection of Cr(VI) without pretreatment, concentration or accumulation steps. ### Main Results - **High Sensitivity**: The developed electrochemical sensor has a detection sensitivity for Cr(VI) of 0.88 μA μM⁻¹ cm⁻². - **Low Detection Limit**: The detection limit is as low as 4.0 nM (signal - to - noise ratio S/N = 3). - **Wide Linear Range**: The linear range is from 0.2 μM to 24.1 μM. - **Good Selectivity**: It has good anti - interference ability against other common interfering ions such as Fe(III) and Cr(III). - **Verification of Practical Application**: Cr(VI) was detected in tap water and lake water, and the recovery rate was between 96% and 108%, indicating that the sensor is reliable in practical applications. ### Conclusion This study successfully developed an electrochemical sensor based on titanium carbide nanofiber arrays coated with nitrogen - doped carbon (TiC@CNx NFAs). This sensor exhibits excellent performance in detecting hexavalent chromium (Cr(VI)) in water bodies and has broad application prospects.