Feasibility of Real‐time Cardiac MRI in Mice Using Tiny Golden Angle Radial Sparse
Hao Li,Patrick Metze,Alireza Abaei,Wolfgang Rottbauer,Steffen Just,Qinghua Lu,Volker Rasche
DOI: https://doi.org/10.1002/nbm.4300
2020-01-01
NMR in Biomedicine
Abstract:Cardiovascular magnetic resonance imaging has proven valuable for the assessment of structural and functional cardiac abnormalities. Even although it is an established imaging method in small animals, the long acquisition times of gated or self‐gated techniques still limit its widespread application. In this study, the application of tiny golden angle radial sparse MRI (tyGRASP) for real‐time cardiac imaging was tested in 12 constitutive nexilin (Nexn) knock‐out (KO) mice, both heterozygous (Het, N = 6) and wild‐type (WT, N = 6), and the resulting functional parameters were compared with a well‐established self‐gating approach. Real‐time images were reconstructed for different temporal resolutions of between 16.8 and 79.8 ms per image. The suggested approach was additionally tested for dobutamine stress and qualitative first‐pass perfusion imaging. Measurements were repeated twice within 2 weeks for reproducibility assessment. In direct comparison with the high‐quality, self‐gated technique, the real‐time approach did not show any significant differences in global function parameters for acquisition times below 50 ms (rest) and 31.5 ms (stress). Compared with WT, the end‐diastolic volume (EDV) and end‐systolic volume (ESV) were markedly higher ( P < 0.05) and the ejection fraction (EF) was significantly lower in the Het Nexn‐KO mice at rest ( P < 0.001). For the stress investigation, a clear decrease of EDV and ESV, and an increase in EF, but maintained stroke volume, could be observed in both groups. Combined with ECG‐triggering, tyGRASP provided first‐pass perfusion data with a temporal resolution of one image per heartbeat, allowing the quantitative assessment of upslope curves in the blood‐pool and myocardium. Excellent inter‐study reproducibility was achieved in all the functional parameters. The tyGRASP is a valuable real‐time MRI technique for mice, which significantly reduces the scan time in preclinical cardiac functional imaging, providing sufficient image quality for deriving accurate functional parameters, and has the potential to investigate real‐time and beat‐to‐beat changes.
What problem does this paper attempt to address?