Misfire-short-circuit Coupling Fault Diagnosis in Hybrid Electric Vehicle Generator Set

Xiaowei Xu,Xue Qiao,Jingyi Feng,Zhenxing Liu,Feng Qian
DOI: https://doi.org/10.1109/cac48633.2019.8997232
2019-01-01
Abstract:In order to solve the problem of misfire-short-circuit coupling faults that may occur during the actual operation of the extender, it is difficult to diagnose with a single mechanical or electrical parameter. Firstly, the mathematic model of generator in normal and fault state is established, then the rigid-flexible hybrid dynamic model of engine is built by ADAMS, which is imported into MATLAB to realize the joint simulation of the extender. Short-circuit fault and misfire-short-circuit coupling fault are simulated in the extender system. Current and electromagnetic torque signals under normal and fault conditions using are analyzed by harmonic analysis method, from which the misfire-short-circuit coupling fault characteristic parameters are extracted. The results show that short-circuit fault causes 1.0 harmonics of current to increase and 2.0 harmonics of electromagnetic torque to change greatly. Misfire fault will cause fluctuations of current and electromagnetic torque, and produce 0.5 harmonics and fractional spectrum components. In the state of misfire-short-circuit coupling fault, the magnitude of three-phase current and electromagnetic torque increases with the degree of misfire failure. The increase of 0.5 harmonic and 1 harmonic can be used as the basis for judging the coupling fault.
What problem does this paper attempt to address?