Effect of thyrotrophin-releasing hormone on serum levels of pituitary hormones in men and women.
P. Torjesen,E. Haug,T. Sand
DOI: https://doi.org/10.1530/ACTA.0.0730455
1973-07-01
Acta Endocrinologica
Abstract:The rapid iv administration of 0.5 mg of synthetic thyrotrophin-releasing hormone (TRH) increased the serum thyroid-stimulating hormone (TSH) concentration in 20 normal subjects from baseline levels of 2.0 \m=+-\0.5 ng/ml (sem) to peak values of 6.0 \m=+-\0.7 ng/ml (sem) in women and 4.5 \m=+-\0.5 ng/ml (sem) in men. The maximal increase occurred 30 min after TRH. The serum growth hormone (HGH) concentrations increased from baseline levels of 2.6\m=+-\1.0 ng/ml (sem) to peak values of 7.8\m=+-\1.3 ng/ml (sem) in women. In men there was no rise in the serum HGH concentrations. The serum levels of luteinizing hormone (LH) and folliclestimulating hormone (FSH) did not change significantly. In patients with hyperthyroidism the serum TSH concentrations did not change following TRH. Patients with primary hypothyroidism showed an exaggerated and prolonged increase in serum TSH concentrations after TRH administration. A routine TRH-stimulation test is proposed. The hypothalamus produces a thyrotrophin-releasing hormone (TRH) which controls the secretion of thyrotrophin (TSH) (Reichlin 1966). Iv injection of synthetic TRH significantly increases serum TSH concentration (Fleischer et al. 1972; Karlberg et al. 1971; Anderson et al. 1971; Guai et al. 1972). The specificity of the action of TRH on the anterior pituitary hormones is still a matter of discussion. Downloaded from Bioscientifica.com at 11/16/2018 04:09:26PM via free access The purposes of the present study were to evaluate the effects of TRH on serum levels of TSH, follicle-stimulating hormone (FSH), luteinizing hormone (LH), and growth hormone (HGH) in healthy men and women, and to pro¬ vide data necessary for the utilization of synthetic TRH as a clinical test. MATERIAL AND METHODS TRH stimulation test The TRH (pyroGlu-His-Pro-NHj) was kindly supplied by Farbwerke Hoechst AG in the free amide form. Each ampoule contained 0.5 mg TRH as dry powder which was dissolved in 1.0 ml distilled water immediately before use. 0.5 mg TRH was given as a rapid iv injection. Blood samples were drawn through an indwelling plastic cannula 15 min before, and 0, 15, 30, 45, 60 and 90 min after the injection. All samples were assayed for TSH. In addition the samples drawn at 0, 15 and 90 min were assayed for HGH. LH and FSH were determined in the samples drawn at 0 min and in the samples showing a maximal increase in serum TSH. The subjects were fasted after midnight and were supine, but awake during the test. The tests were performed between 8 and 10 a. m. Normal subjects Healthy volunteers (10 males and 10 females) 20 to 40 years of age were studied. Patients All patients had received no treatment at the time of the study. Radioimmunoassay procedure The radioimmunoassays for TSH, FSH, LH and HGH were carried out by a similar technique (Sand Se Torjesen 1973). It is described in some detail for TSH. Reagents Assay buffer. 0.05 ml/1 K-phosphate buffer pH 7.5, 0.1 mol/1 NaCl, 0.05 Vo NaN3 and 0.2 % bovine serum albumin (Sigma). Charcoal-dextran suspension. 3 Vo charcoal (Norit A Neutral Pharmaceutical Grade, Amend Drug & Chemical Company, New York) and 0.3 */o Dextran 250 (Pharmacia, Uppsala, Sweden) in assay buffer without bovine serum albumin. TSH standards. Human pituitary TSH 68/38 was provided by the National In¬ stitute for Medical Res., Mill Hill, London. '2SI-TSH. Highly purified TSH obtained from Calbiochem (Lot no. 079506) was iodinated with 12^I (Radiochemical Centre, Amersham or NEN Chemical GmbH), 1 mCi/5 μg TSH, according to the method described by Greenwood et al. (1964). Iodination was performed every second month, and each week the 125I-TSH was rechromatographed on a Sephadex G-150 column (1.5 20 cm) at 4°C in assay buffer. Antiserum. Antiserum against TSH prepared in rabbits was obtained from Cal¬ biochem (Lot no. 079507). Downloaded from Bioscientifica.com at 11/16/2018 04:09:26PM via free access Assay procedure All determinations were performed in duplicate. Sample tubes contained 200 μ serum, 100 μ l^I-TSH solution (20 000 dpm), 600 id assay buffer, and 100 μ anti¬ serum diluted 1:40 000 in assay buffer. Tubes for the standard curve contained 200 μ of standard TSH dissolved in assay buffer, instead of serum. Control tubes con¬ tained either 200 ul of serum of 200 μ of assay buffer, 100 ul 12T-TSH solution, 700 «1 assay buffer and no antiserum. The tubes were incubated for three days at 4°C. After incubation 200 ul of human serum was added to the tubes that did not contain serum during the incubation. 4 ml of charcoal-dextran suspension was then added to all the tubes. After 60 min of rotation on a Hetomix rotor at room tempera¬ ture, the tubes were centrifuged for 5 min at 2800 x g. The charcoal precipitate was washed once with assay buffer. Calculations The charcoal precipitates containing free hormone were counted in an autogamma counter. The results were expressed as the amount of free radioactive hormone in per cent of the total amount added. LH, FSH and HGH assay FSH used for iodination and standards was obtained from Calbiochem (Lot no. 153145), 2600 IU (2nd IRP-HMG) per mg. LH used for iodination and standards was prepared in our laboratory according to the method of Hartree et al. (1964). It con¬ tained 14 300 IU (2nd IRP-HMG) per mg. HGH used for iodination and standards was provided by Dr. Trygstad (Trygstad Se Foss 1971). FSH (Calbiochem), human chorionic gonadotrophin (HCG) (Sand Se Torjesen 1973) and HGH (Norman Sc Turter 1970) antisera were prepared by immunizing rabbits. The antisera were used in final dilutions of 1:8000, 1:200 000 and 1:50 000, respectively. RESULTS Validity of the TSH assay Sensitivity. The sensitivity was calculated from the precision at zero quantity of unlabelled hormone in six consecutive standard curves (Ekins 8c Newman 1970). 2 sd at zero quantity of unlabelled hormone was calculated to 1 per cent of total counts, corresponding to 0.16 ng TSH in the standard curve. This gives a limit of detection of 0.8 ng TSH/ml serum. Accuracy. The recovery of 1.3-10 ng of TSH added to one ml of serum from four euthyroid patients was: 93 % ± 20 °/o (sd), n= 10. Reproducibility (between-assay precision). Mean: 5.4 ng/ml ± 0.7 ng/ml (sd), coefficient of variation (CV): 13 °/o, = 5. Precision (within-assay precision). Low range: mean: 3.3 ng/ml + 0.25 ng/ml (sd, paired determinations), CV: 8 °/o, = 30. Intermediate range: Mean: 6.9 ng/ml ± 0.5 ng/ml (sd, paired determinations), CV: 7 °/o, = 30. High range: Mean: 20 ng/ml ± 2.1 ng/ml (sd, paired determinations), CV: 11 %, = 30. Downloaded from Bioscientifica.com at 11/16/2018 04:09:26PM via free access Table 1. Normal serum levels of TSH, FSH, LH and HGH.