Experimental Study on the Separation Performance of a Full-Scale SG Steam-Water Separator

Li Liu,Bingbin Ying,Hanyang Gu,Dehui Xu,Chao Huang,Shuo Chen
DOI: https://doi.org/10.1016/j.anucene.2020.107330
IF: 1.9
2020-01-01
Annals of Nuclear Energy
Abstract:Steam separator package including swirl vane separator, gravity and dryer is crucial for guaranteeing steam humidity below 0.1% in SG. In this paper, a high-pressure flow system is designed to study the performance of a full-scale steam separator package at a rated pressure of 6 MPa and temperature of 275.6 degrees C. To obtain separation efficiency, moisture carryover and pressure drop of each stage, the Reynolds number steam and water are 1 x 10(6)-6 x 10(6) and 8.27 x 10(5)-3.2 x 10(6), corresponding to 25-145% load. Results indicate that the separation efficiency ranges from 97 to 99%, 0.5 to 2% and 0.2 to 0.75% for separator, gravity and dryer. The moisture carryover ranges from 2 to 16% and 1 to 4% for separator and gravity, and is below 0.1% at dryer outlet. The pressure drop ranges from 2 to 24 kPa and 0.3 to 3 kPa for separator and dryer. Empirical correlations for swirl vanes are proposed, which are responsible for more than 85% and 70% of total separation efficiency and pressure drop. (C) 2020 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?