Development of imaging x-ray telescopes at Tongji University

Zhanshan Wang,Yingyu Liao,Zhengxiang Shen,Qiushi Huang,Bin Ma,Zhong Zhang,Xiaoqiang Wang,Kun Wang,Jun Yu,Shenghao Chen,Zhenbo Wei,Shuang Ma,Yang Yang,Chun Xie,Vadim Burwitz
DOI: https://doi.org/10.1117/1.JATIS.5.4.044010
2019-01-01
Journal of Astronomical Telescopes Instruments and Systems
Abstract:The imaging x-ray telescope (IXT) was first developed at the Institute of Precision Optical Engineering of Tongji University in 2007. Since then, we have made great progress on the development of mirror fabrication, coatings, and optic assembly. In this paper, we intend to provide an overview of the progress. Currently, we can routinely produce cylindrical mirror substrates with angular resolution of 30 " to 60 ". To improve the effective area, coatings using C, Ni, and Pt layers were designed and achieved a high reflectivity at 0.5 to 10 keV. During the optic assembly, an in-situ measurement system and a three-dimensional ray-tracing program have been developed, thus guiding the assembly process in real time. Several prototypes have been fabricated, and one of them with 21 mirror layers was calibrated at the MPE PANTER x-ray test facility in Germany. The IXT prototype, with a focal length of 2052.5 mm, is characterized by a measured half-power diameter of 111 " and effective area of 39 cm(2) at 1.49 keV. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
What problem does this paper attempt to address?