Preresection Stained Glue Injection to Localize Pulmonary Small Nodules and Ground-glass Opacities

Jian Wang,Li-Bin Gao,Hong Zhang,Liang Liu,Wan-Yin Shi
DOI: https://doi.org/10.1097/rti.0000000000000479
IF: 5.528
2020-01-01
Journal of Thoracic Imaging
Abstract:OBJECTIVE:We sought to introduce a localization procedure (methylene blue-stained N-butyl cyanoacrylate and N-octyl cyanoacrylate glue) in localizing pulmonary small nodules and ground-glass opacities before thoracoscopic resection, and to evaluate its efficacy.METHODS:A total of 20 patients with pulmonary small nodules and/or ground-glass opacities, who underwent video-assisted thoracoscopic surgery from August 1, 2017 to March 1 2018, were included in the study.RESULTS:A total of 24 lesions in 20 patients underwent blue-stained glue localization. The success rate of localization was 100%, with a mean dose of 0.04±0.01 mL blue dye and 1 mL glue used for each lesion. The average time for the whole localization procedure was 15.4±6.3 minutes. All lesions were intraoperatively localized by visual inspection in combination with palpation. The complications related to the localization procedure included mild pneumothorax occurring in 9 patients and minor pulmonary hematoma in 4 patients. No pain or distress was reported.CONCLUSIONS:Blue-stained glue injection is technically feasible and safe to localize pulmonary small nodules and ground-glass opacities before thoracoscopic resection.
What problem does this paper attempt to address?