A Highly Efficient and Energy-Saving Magnetically Induced Membrane Vibration System for Harvesting Microalgae.

Zhenyu Zhao,Matthias Mertens,Yun Li,Koenraad Muylaert,Ivo F. J. Vankelecom
DOI: https://doi.org/10.1016/j.biortech.2019.122688
IF: 11.4
2019-01-01
Bioresource Technology
Abstract:The optimal operational parameters of a second generation magnetically induced membrane vibration (MMV) system were determined using the response surface methodology (RSM) combined with single-factor experiments. The membrane surfaces were characterized by scanning electron microscopy (SEM) and algae cell states by inverted microscopy. The effect of an intermittent vibration strategy on filtration performance and energy consumption was studied. The results showed that the responses could be fitted by RSM models. High membrane flux, low energy consumption, efficient fouling control and no damage to the microalgae could thus be realized. The filtration strategy tests suggested that an intermittent cycle time of 4 min with 50% vibration rate could be the best vibration strategy for harvesting the microalgae under investigation.
What problem does this paper attempt to address?