Feasibility of T1 mapping with histogram analysis for the diagnosis and staging of liver fibrosis: Preclinical results

Qing Wang,HaiFeng Liu,ZuHui Zhu,Ye Sheng,YaNan Du,YuFeng Li,JianHong Liu,JiLei Zhang,Wei Xing
DOI: https://doi.org/10.1016/j.mri.2020.11.006
IF: 3.13
2021-02-01
Magnetic Resonance Imaging
Abstract:<h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Purpose</h3><p>To compare the diagnostic accuracy of parameters derived from the histogram analysis of precontrast, 10-min hepatobiliary phase (HBP) and 20-min HBP T1 maps for staging liver fibrosis (LF).</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Methods</h3><p>LF was induced in New Zealand white rabbits by subcutaneous injections of carbon tetrachloride for 4–16 weeks (<em>n</em> = 120), and 20 rabbits injected with saline served as controls. Precontrast, 10-min and 20-min HBP modified Look-Locker inversion recovery (MOLLI) T1 mapping was performed. Histogram analysis of T1 maps was performed, and the mean, median, skewness, kurtosis, entropy, inhomogeneity and 10th/25th/75th/90th percentiles of T1<sub>native</sub>, T1<sub>10min</sub> and T1<sub>20min</sub> were derived. Quantitative histogram parameters were compared. For significant parameters, further receiver operating characteristic (ROC) analyses were performed to evaluate the potential diagnostic performance in differentiating LF stages.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3><p>Finally, 17, 20, 21, 21 and 20 rabbits were included for the F0, F1, F2, F3, and F4 pathological grades of fibrosis, respectively. The mean/75th of T1<sub>native</sub>, entropy of T1<sub>10min</sub> and entropy/mean/median/10th of T1<sub>20min</sub> demonstrated a significant good correlation with the LF stage (|<em>r</em>| = 0.543–0.866, all <em>P</em> &lt; 0.05). The 75th of T1<sub>native</sub>, entropy<sub>10min</sub>, and entropy<sub>20min</sub> were the three most reliable imaging markers in reflecting the stage of LF. The area under the ROC curve of entropy<sub>20min</sub> was larger than that of entropy<sub>10min</sub> (<em>P</em> &lt; 0.05 for LF ≥ F2, ≥F3, and ≥ F4) and the 75th of T1<sub>native</sub> (<em>P</em> &lt; 0.05 for LF ≥ F2 and ≥ F3) for staging LF.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusion</h3><p>Magnetic resonance histogram analysis of T1 maps, particularly the entropy derived from 20-min HBP T1 mapping, is promising for predicting the LF stage.</p>
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?