Optimization of Buffer Gas Compositions in Atomic Vapor Cell for Coherent Population Trapping Atomic Clock

Li Yunchao,Hu Xuwen,Zhang Lu,Liu Zhaojun,Zhang Kaifang,Mou Shihao,Yan Shubin,Zhang Yanjun
DOI: https://doi.org/10.3788/lop56.120201
2019-01-01
Laser & Optoelectronics Progress
Abstract:Frequency stability is an important indicator to evaluate the performance of a coherent population trapping (CPT) atomic clock, and the type and pressure ratios of the buffer gas compositions inside an atomic vapor cell arc main factors influencing frequency stability. In this study, the temperature frequency shift caused by buffer gas compositions, i. e. , Ar and N-2, was simulated and analyzed theoretically, and the temperature shifts caused by different pressure ratios of buffer gas compositions were tested experimentally. The optimal ratio of buffer gas compositions in the atomic vapor cell was determined based on the theoretical and experimental results, and the corresponding operation point for the minimum temperature frequency shift was found. The research results provide a valuable reference for selecting the pressure ratio of buffer gas compositions and the operation temperature of the atomic vapor cell for a CPT atomic clock.
What problem does this paper attempt to address?