A Parameterized Rational-Fraction Fitting Algorithm for Numerical Oscillation Suppression in Weak AC Grid

CHI Yongning,SHU Dewu,ZHANG Chunpeng,WEI Linjun,JIANG Qirong
DOI: https://doi.org/10.13335/j.1000-3673.pst.2016.06.027
2016-01-01
Abstract:1Larges-scale wind or photovoltaic power generations are often located in remote areas with large line impedances and many disturbances. When simulating above system with electromagnetic transient (EMT) analysis, classical numerical algorithms (e.g. trapezoidal rule) are prone to non-prototype numerical oscillations, resulting in simulation result distortion. Traditional methods involve additional algorithm alteration or damping elements with fixed parameters, limiting algorithm flexibility. In this paper, a new EMT algorithm is proposed based on three order rational approximation of exponential function. This algorithm can adaptively adjust parameters so as to achieve L stability. As the algorithm possesses faster truncation error decay rate, it can suppress numerical oscillations effectively. Numerical oscillation error recurrence formula is formulated to theoretically explain decay characteristics of the proposed algorithm and trapezoidal rule. Simulation results of a weak AC system validate advantages of the proposed method in numerical stability and numerical oscillation suppression.
What problem does this paper attempt to address?